Showing posts with label Formula. Show all posts
Showing posts with label Formula. Show all posts

ATTERBERG LIMITS AND PLASTICITY BASIC INFORMATION AND TUTORIALS


Atterberg limits, named after the Swedish soil scientist A. Atterberg, are water content values at which notable changes in soil behavior occur. The liquid limit , denoted LL or wL, marks the transition between liquid and plastic behavior.

At water contents above the liquid limit the soil behaves as a viscous liquid; below the liquid limit the soil behaves as a plastic solid. The liquid limit is determined in the laboratory by partly filling a standard brass cup with wet soil and cutting a groove of a standard dimension in the soil.

The liquid limit is taken as the water content at which the groove closes a specified amount when the cup is lifted and dropped 1 cm exactly 25 times. The details of the test are given in AASHTO T 89 and ASTM D 4318-93.

The plastic limit, denoted PL or wp, is the transition between plastic and brittle behavior. It is determined in the laboratory as the water content at which a 1/8-inch diameter thread of soil begins to crumble when rolled under the palm of the hand.

Details of the liquid limit and plastic limit tests are provided by AASHTO T 90 and ASTM D 4318-93. The shrinkage limit, denoted SL or wS, is the water content below which the soil no longer reduces in volume when the water content is reduced.

Although Atterberg limits are water contents and are properly decimals or percentages, they are usually expressed as an integer percentage without a percent sign. Thus, a liquid limit of 40% is usually reported as LL = 40.

The plasticity index, denoted PI or IP, is the difference of the liquid limit and the plastic limit:

PI = LL – PL

The liquidity index, denoted LI or IL , is a measure of the natural water content (w) relative to the plastic limit and the liquid limit:

LI = Il = (W-pl)/ (LL-PL)

MURRAY CRITERION FOR WALKING VIBRATIONS TUTORIALS


In the criterion presented by Murray, an acceptable steel floor system is predicted, with respect to vibration levels due to walking excitation, if the dynamic criterion below is met.

This criterion is applicable to offices and residences with fundamental natural frequencies below 10 Hz.

Murray criterion:
D > 35Aoƒ + 2.5

where D = damping in floor system, expressed as a percent of critical

Ao = maximum initial amplitude of the floor system due to a heel-drop excitation, in

ƒ = first natural frequency of the floor system, Hz

This criterion is only applicable for the units specified. The reader is cautioned against using other units.

CIVIL ENGINEERING FORMULAS FREE EBOOK DOWNLOAD LINK

CIVIL ENGINEERING FORMULAS FREE DOWNLOADS
Civil Engineering Free E-Book Download Link


Fully updated and packed with more than 500 new formulas, this book offers a single compilation of all essential civil engineering formulas and equations in one easy-to-use reference.


Practical, accurate data is presented in USCS and SI units for maximum convenience. Follow the calculation procedures inside Civil Engineering Formulas, Second Edition, and get precise results with minimum time and effort.

Each chapter is a quick reference to a well-defined topic, including:

Beams and girders
Columns
Piles and piling
Concrete structures
Timber engineering
Surveying
Soils and earthwork
Building structures
Bridges and suspension cables
Highways and roads
Hydraulics, drams, and waterworks
Power-generation wind turbines
Stormwater
Wastewater treatment
Reinforced concrete
Green buildings
Environmental protection

DOWNLOAD LINK!!!
electrical engineering tutorials