Beams shall satisfy the following limitations:
(1) Beams shall be rolled wide-flange or built-up I-shaped
members conforming to the requirements of Section 2.3 of AISC.
(2) Beam depth is limited to W36 (W920) for rolled shapes.
Depth of built-up sections shall not exceed the depth permitted for rolled
wide-flange shapes.
(3) Beam weight is limited to 300 lbs/ft (447 kg/m).
(4) Beam flange thickness is limited to 13/4 in. (44.5 mm).
(5) The clear span-to-depth ratio of the beam shall be
limited as follows:
(a) For SMF systems, 7 or greater.
(b) For IMF systems, 5 or greater.
(6) Width-thickness ratios for the flanges and web of the
beam shall conform to the limits of the AISC Seismic Provisions. When
determining the width-thickness ratio of the flange, the value of bf shall not
be taken as less than the flange width at the ends of the center two-thirds of
the reduced section provided that gravity loads do not shift the location of the
plastic hinge a significant distance from the center of the reduced beam
section.
(7) Lateral bracing of beams shall be provided as follows:
(a) For SMF systems, in conformance with Section 9.8 of the
AISC Seismic Provisions. Supplemental lateral bracing shall be provided at the
reduced section in conformance with Section 9.8 of the AISC Seismic Provisions
for lateral bracing provided adjacent to the plastic hinges.
References to the tested assembly in Section 9.8 of the AISC
Seismic Provisions do not apply. When supplemental lateral bracing is provided,
attachment of supplemental lateral bracing to the beam shall be located no
greater than d/2 beyond the end of the reduced beam section farthest from the
face of the column, where d is the depth of the beam.
No attachment of lateral bracing shall be made to the beam
in the region extending from the face of the column to end of the reduced
section farthest from the face of the column. (b) For IMF systems, in
conformance with Section 10.8 of the AISC Seismic Provisions.
Exception: For both systems, where the beam supports a
concrete structural slab that is connected between the protected zones with
welded shear connectors spaced a maximum of 12 in. (300 mm) on center,
supplemental top and bottom flange bracing at the reduced section is not
required.
0 comments: